View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000315 | Heureka | TPG | public | 2020-02-08 10:19 | 2020-02-11 11:09 |
Reporter | Peder | Assigned To | Linus | ||
Priority | urgent | Severity | major | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Product Version | 2.15.0.1 | ||||
Target Version | 2.15.1 | Fixed in Version | 2.15.1 | ||
Summary | 0000315: Exception when running TPG for FMPP treatment unit | ||||
Description | Exception "Object reference not set..." when running TPG on a FMPP treatment unit, when Apply Treatment Proposal is activated | ||||
Steps To Reproduce | 1. Starta nytt PlanWise-projekt 2. Importera bifogade Ipak-bestånd (bifogar två st i två olika zip-filer). 3. Kör TPG med Apply Treatment Proposal förkryssat. Detta är ett bestånd med ungskogsytor. | ||||
Tags | No tags attached. | ||||
Attached Files | |||||
Product | PlanWise | ||||
|
Ett bestånd till att verifiera buggfix mot |
|
Check for treatment unit proposals was not done properly since addition of Prediction unit proposals. Could result in null reference exception |
Date Modified | Username | Field | Change |
---|---|---|---|
2020-02-08 10:19 | Peder | New Issue | |
2020-02-08 10:19 | Peder | Status | new => assigned |
2020-02-08 10:19 | Peder | Assigned To | => Linus |
2020-02-08 10:21 | Peder | Steps to Reproduce Updated | |
2020-02-08 10:21 | Peder | File Added: 012321 14027 0.zip | |
2020-02-08 10:42 | Peder | File Added: 016325 28406 1.zip | |
2020-02-08 10:42 | Peder | Note Added: 0000303 | |
2020-02-08 10:42 | Peder | Steps to Reproduce Updated | |
2020-02-11 11:08 | Changeset attached | => heureka trunk r20416 | |
2020-02-11 11:08 | Linus | Status | assigned => resolved |
2020-02-11 11:08 | Linus | Resolution | open => fixed |
2020-02-11 11:08 | Linus | Fixed in Version | => 2.15.1 |
2020-02-11 11:08 | Linus | Note Added: 0000304 | |
2020-02-11 11:09 | Linus | Target Version | => 2.15.1 |