View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0000821 | Heureka | TPG | public | 2026-06-04 14:35 | 2026-06-04 14:35 |
| Reporter | jonare | Assigned To | |||
| Priority | normal | Severity | minor | Reproducibility | N/A |
| Status | new | Resolution | open | ||
| Product Version | 2.24.1 | ||||
| Target Version | 2.24.2 | ||||
| Summary | 0000821: Enforced thinning grade critieria not used | ||||
| Description | Enforced thinning grade critieria is only evaluated if the ThinningApplicable status is TooHighForFirstThinning. | ||||
| Additional Information | Enforced thinning grade critieria is only evaluated if a enforced thinning is already planned. That can only happen if the basal area is > 0.9 minBasalAreaForThinning, so the evaluation of a enforced thinning will always evaluate true. This check should be done much earlier in the TPG, as to not miss enforced thinnings due to too low basal area for thinning. | ||||
| Tags | No tags attached. | ||||
| Product | General | ||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2026-06-04 14:35 | jonare | New Issue |