View Issue Details

IDProjectCategoryView StatusLast Update
0000198HeurekaTPGpublic2018-04-11 14:43
ReporterLinus Assigned ToLinus  
PrioritynormalSeverityminorReproducibilityalways
Status closedResolutionfixed 
Product Version2.10.3 
Fixed in Version2.11.0 
Summary0000198: Initial bare land is not regenerated when rerunning a simulation when using NFI-data plots as input data
DescriptionEmpty plots are left empty when rerunning a simulation. Also the period midth setting is not carried over for such plots.
TagsNo tags attached.
ProductPlanWise

Activities

Linus

2018-03-20 15:23

administrator   ~0000205

Last edited: 2018-03-20 15:40

19073 - Plots were not regenerated because the treatment program already contained a regeneration, regardless of if it was an initial regeneration or not.

Check for period midth only checked the year of the first treatment to determine if midth was to be used. If that treatment was performed in period 0, no pmidth was assumed.

Issue History

Date Modified Username Field Change
2018-03-20 15:21 Linus New Issue
2018-03-20 15:23 Linus Assigned To => Linus
2018-03-20 15:23 Linus Status new => closed
2018-03-20 15:23 Linus Resolution open => fixed
2018-03-20 15:23 Linus Note Added: 0000205
2018-03-20 15:40 Linus Note Edited: 0000205
2018-04-10 16:01 Peder Product Version => 2.10.3
2018-04-10 16:01 Peder Fixed in Version => 2.11.0
2018-04-11 14:39 Peder Summary Empty plots are not regenerated when rerunning a simulation => Initial bare land are not regenerated when rerunning a simulation
2018-04-11 14:43 Peder Summary Initial bare land are not regenerated when rerunning a simulation => Initial bare land is not regenerated when rerunning a simulation when using NFI-data plots as input data
2018-04-11 14:43 Peder Product General => PlanWise